Fluke MET/CAL Procedure ============================================================================= INSTRUMENT: Soar 5030: (1 year) CAL VER /5520 DATE: 10-Sep-97 AUTHOR: Fluke Corporation REVISION: $Revision: 1.1 $ ADJUSTMENT THRESHOLD: 70% NUMBER OF TESTS: 28 NUMBER OF LINES: 137 CONFIGURATION: Fluke 5520A ============================================================================= # # Compatibility: # 5500/CAL 5.0 or MET/CAL 5.0 or later. # # Subprocedures: # None # # Required Files: # None # # System Specifications: # TUR calculation is based on specification interval of the accuracy file. # The default 5520A accuracy file contains 90 day specs. # # Fluke makes no warranty, expressed or implied, as to the fitness # or suitability of this procedure in the customer's application. # STEP FSC RANGE NOMINAL TOLERANCE MOD1 MOD2 3 4 CON 1.001 DISP {Procedure not formally tested with UUT.} 1.001 DISP {See procedure README file.} 1.002 ASK- R P F V 1.003 ASK+ K X 1.004 HEAD PRELIMINARY INSTRUCTIONS 1.005 DISP Warm-up time: NONE 1.005 DISP Temperature: 18 - 28 degC 1.005 DISP Humidity: <80% 1.006 DISP [32] WARNING 1.006 DISP HIGH VOLTAGE is used or exposed during the performance 1.006 DISP of this calibration. DEATH ON CONTACT may result if 1.006 DISP personnel fail to observe safety precautions. 1.007 HEAD {DC VOLTAGE} 1.008 DISP Press the POWER button to turn the unit ON. 1.008 DISP 1.008 DISP Press the V button to select DC VOLTS. 1.008 DISP 1.008 DISP *NOTE* if necessary press the AC/DC button to select DC. 1.009 DISP Press the AUTO button to select AUTO range. 1.010 DISP Connect the 5520A to the UUT as follows: 1.010 DISP [32] 5520A NORMAL HI to UUT V/OHM 1.010 DISP [32] 5520A NORMAL LO to UUT COM 1.011 HEAD DC VOLTAGE: {200mV Range} 1.012 5520 200 100.0mV 0.25% 0.2U 2W 2.001 HEAD DC VOLTAGE: {2000mV Range} 2.002 5520 2000 1000mV 0.25% 1U 2W 3.001 HEAD DC VOLTAGE: {20V Range} 3.002 5520 20 10.00V 0.25% 0.01U 2W 4.001 HEAD DC VOLTAGE: {200V Range} 4.002 5520 200 100.0V 0.25% 0.1U 2W 5.001 HEAD DC VOLTAGE: {1000V Range} 5.002 5520 1000 1000V 0.25% 1U 2W 6.001 HEAD {AC VOLTAGE} 6.002 DISP Press the AC/DC button to select AC. 6.003 HEAD AC VOLTAGE: {2000mV Range} 6.004 5520 2000 1000mV 0.5% 5U 100H SI 2W 7.001 HEAD AC VOLTAGE: {20V Range} 7.002 5520 20 10.00V 0.5% 0.05U 100H SI 2W 8.001 HEAD AC VOLTAGE: {200V Range} 8.002 5520 200 100.0V 0.5% 0.5U 100H SI 2W 9.001 HEAD AC VOLTAGE: {1000V Range} 9.002 5520 1000 1000V 0.5% 5U 100H SI 2W 10.001 HEAD {DIODE} 10.002 DISP Press the DIODE button to select diode function. 10.003 5520 500mV 5% 1U 2W 11.001 HEAD {RESISTANCE} 11.002 DISP Press the OHMS button to select RESISTANCE. 11.003 HEAD RESISTANCE: {2000 kOhm Range} 11.004 5520 2000 1000kZ 1% 2U 2W 12.001 HEAD RESISTANCE: {20 MOhm Range} 12.002 5520 20 10.00MZ 2% 0.02U 2W 13.001 HEAD RESISTANCE: {200 kOhm Range} 13.002 DISP Connect the 5520A to the UUT as follows: 13.002 DISP [32] 5520A AUX HI to UUT V/OHM 13.002 DISP [32] 5520A AUX LO to UUT COM 13.002 DISP [32] 5520A NORMAL HI to UUT V/OHM 13.002 DISP [32] 5520A NORMAL LO to UUT COM 13.002 DISP Connect the SENSE leads DIRECTLY to the UUT. Connect 13.002 DISP the NORMAL leads to the SENSE leads AT the UUT. 13.003 5520 200 100.0kZ 0.25% 0.1U CW 14.001 HEAD RESISTANCE: {20 kOhm Range} 14.002 5520 20 10.00kZ 0.25% 0.01U CW 15.001 HEAD RESISTANCE: {2000 Ohm Range} 15.002 5520 2000 1000Z 0.25% 1U CW 16.001 HEAD RESISTANCE: {200 Ohm Range} 16.002 5520 200 100.0Z 0.25% 0.3U CW 17.001 HEAD {CONTINUITY} 17.002 DISP Press the OHMS/CONTINUITY button to select CONTINUITY. 17.003 5520 10Z S CW 17.004 EVAL Is there an AUDIBLE TONE present? 18.001 HEAD {DC CURRENT} 18.002 DISP Press the A button to select DC CURRENT. 18.002 DISP 18.002 DISP Press the AUTO button to select AUTO range. 18.002 DISP 18.002 DISP *NOTE* if necessary press the AC/DC button to select DC. 18.003 DISP Connect the 5520A to the UUT as follows: 18.003 DISP [32] 5520A AUX HI to UUT mA 18.003 DISP [32] 5520A AUX LO to UUT COM 18.004 HEAD DC CURRENT: {200uA Range} 18.005 5520 200 100.0uA 0.75% 0.1U 2W 19.001 HEAD DC CURRENT: {2000uA Range} 19.002 5520 2000 1000uA 0.75% 1U 2W 20.001 HEAD DC CURRENT: {20mA Range} 20.002 5520 20 10.00mA 0.75% 0.01U 2W 21.001 HEAD DC CURRENT: {200mA Range} 21.002 5520 200 100.0mA 0.75% 0.1U 2W 22.001 DISP Connect the 5520A to the UUT as follows: 22.001 DISP [32] 5520A 20A to UUT A 22.001 DISP [32] 5520A AUX LO to UUT COM 22.002 HEAD DC CURRENT: {10A Range} 22.003 5520 10 5.00A 1% 0.01U HC 2W 23.001 HEAD {AC CURRENT} 23.002 DISP Press the AC/DC button to select AC CURRENT. 23.003 HEAD AC CURRENT: {10A Range} 23.004 5520 10 5.00A 1.2% 0.05U 100H SI HC 2W 24.001 DISP Connect the 5520A to the UUT as follows: 24.001 DISP [32] 5520A AUX HI to UUT mA 24.001 DISP [32] 5520A AUX LO to UUT COM 24.002 HEAD AC CURRENT: {200uA Range} 24.003 5520 200 100.0uA 1% 0.5U 100H SI 2W 25.001 HEAD AC CURRENT: {2000uA Range} 25.002 5520 2000 1000uA 1% 5U 100H SI 2W 26.001 HEAD AC CURRENT: {20mA Range} 26.002 5520 20 10.00mA 1% 0.05U 100H SI 2W 27.001 HEAD AC CURRENT: {200mA Range} 27.002 5520 200 100.0mA 1.2% 0.5U 100H SI 2W 28.001 END